Skip to main content

Indie game storeFree gamesFun gamesHorror games
Game developmentAssetsComics
SalesBundles
Jobs
TagsGame Engines

Bug Report (Not Truly a Bug) FYI (TMNT+MEDPRO+Stinker Models=Errors, Unless Bus Terminated)

A topic by ROBOT-RANDOM created 19 days ago Views: 88 Replies: 4
Viewing posts 1 to 3
(5 edits)

Summary: Sega Genesis Model 2 VA0 & Sega Genesis Model 1 VA7 often have problems with the MEDPRO if the expansion bus is not terminated. This can cause problems with homebrew games. 

- Game version: All revisions. Cannot be resolved through software completely.

- Platform: Sega Genesis Model 2 VA0 (& Brazilian equivalent), Sega Genesis Model 1 VA7 "Stinker" model. It does not ALWAYS effect even these sub-models because some had hardware fixes at the factory. Be aware that there were actually over a half dozen sub-models of the Model 1, over a half dozen sub-models of the Model 2, and two sub-models of the Model 3. Less than 1/14th of all Genesis consoles have this problem.

- What happened vs. what you expected: While the latest Krikzz firware v26.0925 reduced this problem, it is still an issue with homebrew. The data bus implementation of these particular models introduces noise that interferes with the operation of the MEDPRO.

- Steps to reproduce: Don't try to reproduce it. Terminate the bus on these consoles. The 32X dongle (NOT the 32x itself, but the bus terminator that the earliest ones came with) or a completely inert Sega CD can safely resolve this problem. If you have one of the effected models that starts throwing errors, it could damage the FPGA in the MEDPRO if you keep reproducing the issue. It is an electrical noise problem. There are also DIY guides to creating a terminator on the internet.

- How often it happens (always / sometimes / once): If you have an effected Sega Genesis model that was never factory corrected, it is guaranteed to happen.

- Screenshot or video if possible: This is a known issue that was discussed at length in the Krikzz forums. It is an obscure problem because the sub-models that have this issue also have sub par sound quality and so usually people that have MEDPRO would not even own them.

Supposedly, to clean up the noise you would run a 4.7k Ohm resistor from each of the 16 system data bus lines to the ground pin. A DIY should not be attempted without extensive knowledge, detailed schematics, and high technical skill.

Here is what the 32x Dongle (NOT THE 32X) looks like. It is ALSO required to run the 32X on the same consoles with this defect.

Developer

Thank you for such a detailed report! This is really useful, and I appreciate you taking the time to write it up.

Since this is an electrical issue on specific console revisions rather than something in the game's code, I can't fix it from the software side. What I've done instead is document it as a pinned known issue in the Community tab, with the workaround (terminating the expansion bus) so other players with those consoles can find it: 馃搶 Known issue: random errors on some Genesis consoles with Mega EverDrive PRO - TMNT: Arcade Game - Megadrive Port community - itch.io

I鈥檒l double-check that the ROM doesn鈥檛 rely on open-bus behavior.

Thanks again for helping improve the port!

Do inexpensive Everdrives, such as the V3 models sold on AliExpress, exhibit this issue in affected hardware revisions ? And when attaching a Sega 32X, does the 32X need to be powered on to resolve this problem ?

Not the 32x. The 32x Dongle. It is a simple thing that simply sticks on the expansion bus. In fact, the same consoles that have this problem with the MEDPRO, also won't work with the 32x Unless they have the 32x dongle.